Estimating the Greenhouse Gas Emission Potential Due to Construction Work on the 225 kV Segou - Bamako High Voltage BI-Ternal Electric Line in Mali in The Context of Climate Change

Tolidji Blaise Donou

International Bank for Reconstruction and Development (IBRD), BP2445, Cotonou, Benin.

Zakari Soufouyane

Laboratory of Cartography Remote Sensing and GIS (LaCarto), University of Abomey-Calavi (UAC), 10 BP 1082, Cadjèhoun, Cotonou, Benin.

Olojoba Africa Eshogba

International Bank for Reconstruction and Development (IBRD), BP2445, Cotonou, Benin.

ISSA Maman-Sani

African Development Bank (AfDB), Benin.

Issifou Moumouni Yaya *

Laboratory of Cartography Remote Sensing and GIS (LaCarto), University of Abomey-Calavi (UAC), 10 BP 1082, Cadjèhoun, Cotonou, Benin.

*Author to whom correspondence should be addressed.


Abstract

The aim of this study is to assess the carbon emissions resulting from the construction of the power line linking Bamako to Ségou. It focuses on direct emissions, more specifically those linked to the degradation and desctruction of the vegetation cover in the project right-of-way. To collect the data, surveys were set up on the project right-of-way, through which 3302 trees were inventoried in situ at the three sites. Circumference was measured at 1.30 m from the ground surface. Allometric equations for direct biomass estimation were used as a predictor o f tree diameter. Emission factors were then used to estimate the potential greenhouse gas emissions resulting from tree felling during power line construction. The standard error associated with the carbon fraction in dry biomass was calculated. In the Ségou, Koulikoro and Dioïla project areas, there are a number of plant species that provide local populations with various ecosystem services, including micro-climate regulation through carbon sequestration or absorption of atmospheric CO2. The implementation of the project will undoubtedly result in the felling of these trees. This felling will generate emissions of 22.11 t.eqCO2/ha in Ségou, 16.56 t.eqCO2/ha in Koulikoro and 15.43 t.eqCO2/ha in Dioïla. Across Ségou, Koulikoro and Dioïla, the trees in the project right-of-way represent a reservoir of 34.04 t/ha of above-ground woody biomass. This biomass represents a carbon stock of around 16.58 t.C/ha. This carbon stock will be transformed into a carbon source with emissions of 60.78 t.eqCO2/ha if the trees in the power line right-of-way are systematically felled. Mitigation measures are therefore urgently needed, with compensatory reforestation areas planted with species with high carbon sequestration potential.

Keywords: Mali, Greenhouse gas emission potential, power lines, emissions accounting, carbon, carbon dioxide


How to Cite

Donou, Tolidji Blaise, Zakari Soufouyane, Olojoba Africa Eshogba, ISSA Maman-Sani, and Issifou Moumouni Yaya. 2024. “Estimating the Greenhouse Gas Emission Potential Due to Construction Work on the 225 KV Segou - Bamako High Voltage BI-Ternal Electric Line in Mali in The Context of Climate Change”. International Journal of Environment and Climate Change 14 (11):408-18. https://doi.org/10.9734/ijecc/2024/v14i114556.